| Installation cycle | StandardNormalbetrieb | operationRuhezustand | Idle state | Radio failure | Forced heating | Freeze Protection | CommentsFunkausfall | Erzwungenes Heizen | Frostschutz | ||||||
Kommentare |
| Valve target Ventilziel % OrOder Flow target temperatureVorlaufsolltemperatur
| Phases between monitoring and communicating | Uplinks not received by the gateway | Valve opens to 50% (or remains in current position if current position is Phasen zwischen Überwachung und Kommunikation | Uplinks werden nicht vom Gateway empfangen | Ventil öffnet zu 50 % (oder bleibt in der aktuellen Position, wenn die aktuelle Position
| Valve opens to 95%Ventil öffnet zu 95 % (or remains in current position if current position is oder bleibt in der aktuellen Position, wenn die aktuelle Position
| ||||||||
Trigger | Magnetic switch. Join accept from Gateway, & Device is mounted | Internal timer | Internal timer | From activation: No Gateway connect From standard operation: 6 consecutive Gateway communication failures | Battery voltage < 2V | Flow sensor raw temperatureAuslöser | Magnetschalter, Gateway-Verbindung akzeptiert und Gerät ist montiert | Interner Timer | Interner Timer | Ab Aktivierung: Keine Gateway-Verbindung Aus dem Standardbetrieb: 6 aufeinanderfolgende Gateway-Kommunikationsfehler | Batteriespannung < 2V | Ventilsensor Rohwert
| ||||
Radio communication interval Funkkommunikationsintervall (RCI) | 10 seconds for 5 minutesSekunden für 5 Minuten | 5 Minuten 10 minutesMinuten 60 minutesMinuten 120 minutesMinuten 480 minutesMinuten | OFFAUS | Three times Dreimal 30 secondsSekunden Then once Dann einmal 2 minutesMinutenThen Dann 60 minutesMinuten | OFFAUS | OFF | Dynamic change of communication interval AUS | |||||||||
Dynamische Änderung des Kommunikationsintervalls | Default upon activation and no downlinks | Setpoint flow 55°C Flow offset +5°C | Setpoint flow 55°C Flow offset +5°C RCI 60 minutes | Setpoint flow 55°C Flow offset
| No | Yes | No | No | No | No | ||||||
Sensors (flow, ambient) | Active, every 10 seconds | Active | OFF
| Active | OFF | Active, every 2 minutes | ||||||||||
Freeze protection | Active, every 10 seconds | Active, every 150 seconds | OFF | Active, every 150 seconds | OFF | Active | ||||||||||
Motor operation | Reference run. Then active, according to Radio Communication | Active, according to Radio Communication | OFF | Active | OFF | OFF | ||||||||||
Monitoring of battery | Active, every 10 seconds | Active | OFF | Active | Active, every 12 hours | Active, every 2 minutes | ||||||||||
Internal temperature controller | If User Mode is Set Point Flow Temperature: active | If User Mode is Set Point Flow Temperature: active | OFF | If Safety Mode is Set Point Flow Temperature: active | OFF | OFF | ||||||||||
| Nein | Ja | Nein | Nein | Nein | Nein | ||||||||||
Sensoren (Ventil, Umgebung) | Aktiv, alle 10 Sekunden | Aktiv | AUS
| Aktiv | AUS | Aktiv, alle 2 Minuten | ||||||||||
Frostschutz | Aktiv, alle 10 Sekunden | Aktiv, alle 150 Sekunden | AUS | Aktiv, alle 150 Sekunden | AUS | Aktiv | ||||||||||
Motorfunktion | Referenzlauf Dann aktiv, gemäß Funkkommunikation | Gemäß Funkkommunikation aktiv | AUS | Aktiv | AUS | AUS | ||||||||||
Überwachung der Batterie | Aktiv, alle 10 Sekunden | Aktiv | AUS | Aktiv | Aktiv, alle 12 Stunden | Aktiv, alle 2 Minuten | ||||||||||
Interner Temperaturregler | Wenn Benutzermodus Soll-Vorlauftemperatur ist: aktiv | Wenn Benutzermodus Soll-Vorlauftemperatur ist: aktiv | AUS | Wenn der Sicherheitsmodus Soll-Vorlauftemperatur ist: aktiv | AUS | AUS | ||||||||||
Standard bei Aktivierung und keine Downlinks | Sollvorlauf 55°C Offset+5°C | Sollvorlauf 55°C Offset+5°C RCI 60 Minuten | Sollvorlauf 55°C Offset+5°C |
...
Orah footnotes display |
---|