In Port 1 Uplinks, the actuator uses its “Storage Voltage” byte to report the device storage voltage.

Energy storage typical voltage values

Voltage [V] LTO

Fully charged – for charge stop (bq25505 and USB)

2.8

Fully charged – for indicator bit

2.7

Normal operation

2.4 typical (2.0 … 2.8)

Energy storage bit set when below

 2.3

Forced Heating starts when below

 2.

0

2

Forced Heating stops when above

2.4

 Microcontroller

Microcontroller turning off all loads and its own power when below

 1.8

Microcontroller power-up (under hardware-control) when above

2.37

Battery spec HTC1450 (capacity / charge stop / discharge stop)

>500mAh / 2.8V / 1.5V

If, on Port 0, a MAC command 0x06 is sent to the device, the device returns battery level information.

Device Response

Battery Level

0

The device is connected to an external power source

1

2.

00

20 V

1 <= d <= 254

Mathinline
body--uriencoded--2.2 + \frac%7B(d-1) * 0.64%7D%7B253%7D
V

254

2.64 V

255

The device was not able to measure the battery level