Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The Flow Temperature is calculated as follows:

Include Page
MLR003F-K: Flow Temperature Automatic Offset Correction
MLR003F-K: Flow Temperature Automatic Offset Correction

The Ambient Temperature Estimate is calculated as follows:

Mathblock
anchor
alignmentleft
--uriencoded--\begin%7Baligned%7D
\text%7BFlow Temperature Estimate%7D(t) = \frac%7B\sum_%7Bi = t - 5%7D%5e%7Bt%7D%7B\text%7BFlow Sensor Raw Value%7DTemperature%7D(i)%7D%7D%7B6%7D + \text%7BFlow Offset%7D

\\
\\
\\

\text%7BAmbient Temperature Internal%7D(t) = \text%7BAmbient Sensor Raw Value%7D(t) * (\frac %7B\text%7BAmbient Sensor Raw Value%7D(t)%7D %7B\text%7BFlow Temperature Estimate%7D(t)%7D)%5e%7B1.2%7D

\\
\\
\\

\text%7BAmbient Temperature Estimate%7D(t) = \frac%7B\sum_%7B i = t-3%7D%5e%7Bt%7D
%7B\text%7BAmbient Temperature Internal%7D(i)%7D%7D%7B4%7D

\end%7Baligned%7D