Fluid (water) temperature FSRV | Recommended offset for the flow sensor value FTMP applied in FPORT 0x08 (Offset values derived in climate chamber and without valve adapter) |
---|---|
55°C | 10°C |
65°C | 13°C |
70°C | 14°C |
To obtain an estimate of the ambient temperature, the device measures the flow temperature every 5 minutes and performs a moving average across the last 30 minutes. It then performs the following computation
Orah footnote an.spaceKey MH text Ambient Estimate Calculation id 0cv82peijaks
...