User Interface Functionality
The unit has no user-accessible buttons to avoid manipulation of the device in public environments. Installers rely on a pen-shaped magnet to perform tasks related to the installation.
Setting up a Gateway
In a web browser, navigate to the gateway IP address
Login to the gateway
LoRaWAN, Network Settings, Join Delay 5 seconds
LoRaWan, Network Settings, Max Datarate 5 – SF7BW125
Click Submit
Wait for Save and Apply to go red, and then click itFirewall, Settings, Input Filter Rules
Add ‘Allow Inbound’Click Submit
Wait for Save and Apply to go red, and then click it
Pairing the Device with a Room Controller or Gateway
Devices will be accompanied with a spreadsheet containing the following information:
Device EUI
Join EUI
Application Key
The Device EUI is unique to the device and allows identification and communication via LoRaWAN.
The Application Key is randomly generated to ensure secure communication.
To pair a device to a MultiTech gateway:
In a web browser, navigate to the gateway IP address
Login to the gateway
LoRaWAN, Key Management, click Add New
For each device, enter the following details, and then click OK:
Dev EUI (available in the spreadsheet)
App EUI (available in the spreadsheet)
App Key (available in the spreadsheet)
Class: A
Device Profile: LW102-OTA-EU868
Network Profile: DEFAULT-CLASS-AClick Submit
Wait for Save and Apply to go red, and then click it
Unboxing and Assembly
The product consists of the following
Base Plate
Main Housing with Battery disconnected
Screws and dowels
Use the provided screws and dowels to fix the base plate onto the wall
Connect the battery to the holder and mount the main housing onto the base plate
Attaching and Activating a unit
Before mounting the device onto the wall, be sure that the battery is connected (refer to the above section).
Once the device is mounted
Briefly tap the pen magnet on the 20 °C marking (or) 0 °C marking on the product’s cover
The radio establishes a link to the gateway upon successful completion, a double-beep sounds
The unit is now active
Activation only works when the battery is plugged in for the first time. If performed during normal operation, the product will not show any reaction.
Reset (from Normal Operation only)
The RESET function allows the user to restart the device. It is also useful to restore correct operation should a malfunction occur.
To RESET the device,
Hold the pen magnet on the 20 °C marking (or) 0 °C marking on the product’s cover until a beep sounds
The internal microcontroller will reset and restart
The device is now active