The Spreading Factor of the MLR003R device can be changed by sending a downlink to FPORT 4

The MLR003R operates at SF7 by default and can be changed to SF8

Downlink Structure:

MLR003RiEU61-07 FPORT 0x04: LoRa Data Rate

Spreading Factor

Hex Payload

Base64 Payload

SF7

0

AA==

SF8

1

AQ==

 Example for changing the Spreading Factor to SF8

  1. Send the downlink message (Hex: 1 or Base64: AQ==) on FPORT4

  2. The downlink will be sent to the device on the next uplink (Uplink will still be on SF7)

  3. The device will rejoin to the gateway to change the Data Rate

  4. The same downlink message (on step 1) will be sent again on FPORT 4 confirming the SF Change

  5. The device will then send on SF8 from the next uplink onwards