Copyright Micropelt

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Next »

DOWNLINK

BYTE

BIT RANGE

SIZE

OFFSET

ABBREVIATION

DETAILS

1

DB0.7…0.0

8

0

DevStatusReq

Returns the battery level of the end-device

0x06 = Device Status Request

Response is communicated in field “opts” (not in an FPORT 0x00 Uplink)

BYTE

BIT RANGE

SIZE

OFFSET

ABBREVIATION

DETAILS

1

DB0.7…0.0

8

0

0x06

2

DB1.7…1.0

8

8

DevStatusAns

Battery Level

Device Response

Battery Level

0

The device is connected to an external power source

1

2.20 V

1 d 254

254

2.64 V

255

The device was not able to measure the battery level

3

DB2.7…2.0

8

16

DevStatusAns

Demodulation Margin

SNR in dB rounded to the nearest integer value for the last successfully received DevStatusReq command

  • No labels