DOWNLINK
BYTE | BIT RANGE | SIZE | OFFSET | ABBREVIATION | DETAILS | |
1 | DB0.7…0.0 | 8 | 0 | FADD | Flow Raw Value Offset With 2’s complement Default = 0x00 = 0.00°C Res = 0.25°C | |
0x00 | 0.00 | |||||
0x01 | 0.25 | |||||
0x02 | 0.50 | |||||
… | … | |||||
0x7F | 31.75 | |||||
0x80 | -32.00 | |||||
… | … | |||||
0xFF | -0.25 | |||||
2 | DB1.7…1.0 | 8 | 8 | FMUL | Flow Raw Value Multiplication Default = 0x64 = 1.00°C Res = 0.01°C | |
3 | DB2.7…2.0 | 8 | 16 | NFD | Number of most recent Flow Raw Temperature values to delay by (skip) Default = 0 Clamped to [0..=20] | |
4 | DB3.7…3.0 | 8 | 24 | NMAF | Number of values used in calculation of Flow Moving Average Default = 6 Clamped to [1..=20] | |
5 | DB4.7…4.0 | 8 | 32 | NMAA | Number of values used in calculation of Ambient Moving Average Default = 1 Clamped to [1..=20] | |
6 | DB5.7…5.0 | 8 | 40 | NMAE | Number of values used in calculation of Estimate Moving Average Default = 1 Clamped to [1..=20] | |
7 | DB6.7…6.0 | 8 | 48 | RATO | Ratio Offset Default = 0 Res = 0.01 | |
8 | DB7.7…7.0 | 8 | 56 | POW | Ratio Power Default = 0x00 = 1.2 Res = 0.01 |
Tip: To get Temperature Estimation details without changing any options, send an empty FPORT 0x08 Downlink.
UPLINK
Same a Downlink, confirming Uplink settings
Recommended Settings
Scenario | Flow Offset | Flow Multiplication | Flow Delay | Flow Moving Average | Estimate Moving Average | Ratio Power |
---|---|---|---|---|---|---|
Small or well-insulated room | 0.0 | 1.0 | 0 or 1 If > 0, reduce PI-Coefficient KP (see Port 7) | 1.0 + small | ||
Large or poorly-insulated room | 0.0 | 1.0 | Consider using If > 0, reduce PI-Coefficient KP (see Port 7) | 1.0 + big | ||
Unheated Room is warm | 0.0 | 1.0 | 1.0 + small | |||
Unheated Room is cold | 0.0 | 1.0 | 1.0 + big | |||
Temperature close to the radiator is desired | 0.0 | 1.0 | 1.0 + small | |||
Temperature far from the radiator is desired | 0.0 | 1.0 | 1.0 + big | |||
Flow Temperature fluctuates | 0.0 | 1.0 | Use to smooth | |||
Estimated Temperature fluctuates | 0.0 | 1.0 | Use to smooth | |||
Device is mounted above an exposed pipe | Use to compensate | Use to compensate |